腐蚀声发射信号降噪方法
Noise reduction method of corrosion acoustic emission signal
-
摘要: 为了从复杂背景噪声中有效地检测出腐蚀声发射信号,采用短时分形维数和离散分数余弦变换相结合的降噪方法,利用声发射检测系统,对6% FeCl3·6H2O溶液中Q235钢板的全面腐蚀和局部腐蚀声发射信号进行了降噪处理。实验结果表明,腐蚀声发射信号分别加入白噪声、有色噪声和粉红噪声,在输入信噪比为0~15dB的条件下,此方法降噪效果与标准离散余弦、离散分数余弦变换方法相比,输出信噪比最高可提升8 dB。所述降噪方法对检测腐蚀声发射信号以及对金属剩余寿命的评价具有一定意义。Abstract: The general corrosion and local corrosion of Q235 steel was tested by acoustic emission detecting system under 6%FeCl3-6H2O solution to effectively detect the corrosion acoustic emission signal from complex background noise.The short-time fractal dimension and discrete fractional cosine transform methods are combined to reduce noise.The input SNR is 0~15 dB while corrosion acoustic emission signals being added with white noise,color noise and pink noise respectively.The results show that the output signal-to-noise ratio is improved by up to 8 dB compared with discrete cosine transform and discrete fractional cosine transform.The above-mentioned noise reduction method is of significance for the identification of corrosion induced acoustic emission signals and the evaluation of the metal remaining life.