EI / SCOPUS / CSCD 收录

中文核心期刊

关于宽带和窄带超声血流速度测量方法的评价

An assessment on the wideband and narrowband methods of ultrasonic blood flow measurements

  • 摘要: 本文对现有的几种超声血流速度测量方法做了细致的分析和计算机仿真研究,指出了各种方法的本质特点和他们之间的联系。理论分析和仿真的结果表明;脉冲多普勒方法和自相关法是本质上相同的两种窄带估计方法,由于它们对信号做的窄带假设与实际的信号有一定的差别,导致它们的估计性能较差;一方面不能充分利用多次回波的数据,另一方面还存在着严重的速度混叠现象,信号的频带愈宽,估计的效果愈差.时域互相关法、宽带极大似然法和二线傅氏变换法是三种宽带估计方法,其中时域互相关法和二维傅氏变换法结果上是完全相同的。宽带估计方法明显优于窄带方法,它们不仅有较高的速度分辨率并对速度混叠分量有很好的抑制作用,而且随着信号频带的增加和采样数据的延长,估计的质量还可以得到进一步的提高。

     

    Abstract: The currently used methods of ultrasonic blood flow measurements are studied in this paper.Their inherent characteristics and relations are pointed out. Pulsed Doppler system and autocorrelation method are essentially the same narrowband estimators with the presumption of narrowband signals.Since the presumption is not fulfilled by the real ultrasonic signals, they give the results with low velocity resolution and probably the aliased spectrum. The wider the frequency band of the signals are, the worse the results will be. Time domain crosscorrelation technique, wideband maximum likelihood estimation and 2D Fourier transform method are three wideband techniques. The high velocity resolution and low probability of aliasing can be achieved by these wideband techniques. Moreover, the better estimations come out with wider signal frequency band and the more pulse echoes.

     

/